MZJ-400D/24.48A Contactor

This series of products features one normally open contact with a load current rating of 400 A. It offers a simple structure and reliable performance, making it suitable for programmable power supplies, uninterruptible power supply (UPS) systems, forklifts, electric vehicles, sightseeing vehicles, and construction machinery, among other applications.

  • Application-based electrical specification review
  • Electrical and mechanical compatibility
  • Technical discussion for OEM requirements
  • Sample evaluation and bulk sourcing coordination
Request a quote

Industrial Contactor Specifications

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

MZJ-400D/24.48A Contactor

Rated contact voltage
48 V DC
Rated contact current
400 A
Rated coil voltage
24 V DC
Main Technical Specifications
Product ModelMZJ-400D/24.48A
Rated voltage of contact circuit (V DC)48
Rated current of contact circuit (A)400
Rated coil voltage Ue (V DC)24
Operating voltage in cold state (V)Maximum pickup voltage at (20±5)℃16.8
Minimum release voltage at (20±5)℃2.4
Maximum cold-start inrush current at (20±5)℃ (A)0.42
Maximum cold-start inrush current at (20±5)℃ (A) (duplicate as in original)0.42
Coil voltage fluctuation range±20%
Contact voltage drop (mV)≤80
Insulation resistance (MΩ)≥20
Dielectric test voltageBetween open contacts2500V AC(1min)
Between closed contacts and coil2500V AC(1min)
Maximum operating time at rated voltage
(without coil suppression or freewheeling diode)
Pick-up50ms
Release50ms
Maximum contact bounce time on opening5ms
Maximum switching capacity of main contactsMake-and-break once at 4 times rated load current, with 5 ms energization time
Electrical life at rated voltage (cycles)10,000
Mechanical life (cycles)100,000
Operating specification / Duty cycleContinuous duty (continuous operation)
Environmental Operating Conditions
Product ModelMZJ-400D/24.48A
Ambient Temperature-4 0℃ ~ +7 0℃
Relative Humidity98% at 20℃
Vibration1~50 Hz (for frequency 1~10 Hz, amplitude 25/f²; for frequency 10~50 Hz, amplitude 250/f²)
Shock30m/s
Mounting MethodAny orientation
Degree of ProtectionIP40 (in accordance with GB14048.4, equivalent to IEC60947)

Please refer to the technical datasheet for the exact ratings and operating conditions of each model.

TECHNICAL DRAWINGS

Drawings & diagrams

Open a figure to inspect the dimensions and configuration details.

Designed Around Your
Equipment Requirements

Industrial testing station

Application-Based Selection

Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.

Component testing and inspection

Electrical and Mechanical Compatibility

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

Industrial manufacturing workshop

OEM and Customization Support

Discuss your application, technical parameters and installation constraints with our team. Available options depend on the product platform, engineering feasibility and order requirements.

Industrial Contactor
Applications

  • Industrial machinery and equipment
  • Motor control and electrical control panels
  • Power switching and distribution systems
  • OEM equipment development
  • Application-specific electrical assemblies

Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.

Shanghai Tianyi Hang production floor

OEM Industrial Contactor
Sourcing

For equipment manufacturers, consistent specifications and reliable supply arrangements are important throughout the product lifecycle.

When evaluating a supplier, consider technical documentation, sample verification, production consistency, customization feasibility and long-term sourcing requirements.

Industrial contactor selection guide ↗

FAQ

Frequently
Asked
Questions

Discuss your requirements

Send us your specifications, drawings or existing part number to discuss product suitability, customization feasibility and quotation requirements.

Request a quote
What should I check before selecting this contactor?

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

Can I request a customized contactor?

Customization depends on the model and technical requirements. Share your specifications or drawings so the feasibility of your requested configuration can be reviewed.

Can I request samples before bulk purchasing?

Sample availability, cost and lead time should be confirmed for the selected model before placing an order.

What information is needed for a quotation?

Provide the model number, required quantity, electrical specifications, intended application and any special technical or packaging requirements.