Automated industrial inspection equipment

PRODUCT LINE / CUSTOM SOLUTIONS / TECHNICAL SUPPORT

OEM & Custom Solutions

Explore product specifications, application requirements and customization options for your equipment.

Shanghai Tianyi Hang company reception

FOR OEMS / REF 06

THZ-400C Contactor

This series features a single NO contact, simple construction, and reliable operation. It is applicable to programmable power supplies, UPS systems, forklifts, EVs, sightseeing vehicles, construction machinery, and the like.

  • Application-based electrical specification review
  • Electrical and mechanical compatibility
  • Technical discussion for OEM requirements
  • Sample evaluation and bulk sourcing coordination
Request a quote

Industrial Contactor Specifications

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

THZ-400C Contactor

Load current
400 A
Contact arrangement
Normally open
  • ①Type :THZ
  • ②Lode Current :400A
  • ③series breakdown :C series
  • ④Lode Voltage :48:48 Vd.c.
  • 80:80 Vd.c.
  • ⑤Coil Voltage :48:48 Vd.c.
  • 80:80 Vd.c.
  • ⑥Contact Type N: 1 Form A
  • ⑦Load Termination :Screw-type terminal
  • ⑧ Coil Termination :Spade terminals
  • Wires
  • ⑨ Mounting :No mounting
  • bracket on the side
  • H:With mounting
  • ⑩Permanent Magnet :No Blowouts
  • B:Blowouts
  • ⑪ Coil surge arrester :No Coil surge arrester
  • Coil surge arrester
  • ⑫ Special Code :customer demand(Only for special
  • requirements)

Product characteristics

  • 1.It is preset with permanent magnets, which can quickly extinguish the arc and enhance the product breaking ability;
  • 2.The maximum breaking can reach 600A, 96V DC .
Coil ratings
Rated Voltage
Vd.c.
Operate Voltage
Vd.c.(at
-40 ℃~85 ℃)
Release Voltage
Vd.c. (at
-40 ℃~85 ℃)
Coil Resistance
Ω(at 23 ℃)
Coil Power
W(at
-40 ℃~85 ℃)
48≤36≥4.8152×(1±5%)Approx. 16W
80≤60≥8410×(1±5%)Approx. 16W
  • Contact Arrangement: H 1 Form A 。
  • Contact Material: Copper Alloy 。
  • Contact Resistance: ≤0.5 mΩ (at 20 A) 。
  • Contact Rating: 400 A (240 mm2 wire)。
  • Max. Breaking Current: see4.1 。
  • Max. Switching Voltage: 80 Vd.c.。
  • Min. Applicable Load: 6 Vd.c. 1 A
Current endurance
CurrentDuration
400 Acont.
800 A10s

Condition for current endurance

  • 1.Ambient temperature:85 ℃;
  • 2.Supply rated voltage to coil;
  • 3.The cross section area of wire is 240 mm2 .
Electrical endurance by model
Product modelUnit Weight
THZ-400C/XX-XX-NESB1250g
THZ-400C/XX-XX-NESHB1300g

Please refer to the technical datasheet for the exact ratings and operating conditions of each model.

TECHNICAL DRAWINGS

Drawings & diagrams

Open a figure to inspect the dimensions and configuration details.

Designed Around Your
Equipment Requirements

Industrial testing station

Application-Based Selection

Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.

Component testing and inspection

Electrical and Mechanical Compatibility

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

Industrial manufacturing workshop

OEM and Customization Support

Discuss your application, technical parameters and installation constraints with our team. Available options depend on the product platform, engineering feasibility and order requirements.

Industrial Contactor
Applications

  • Industrial machinery and equipment
  • Motor control and electrical control panels
  • Power switching and distribution systems
  • OEM equipment development
  • Application-specific electrical assemblies

Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.

Shanghai Tianyi Hang production floor

OEM Industrial Contactor
Sourcing

For equipment manufacturers, consistent specifications and reliable supply arrangements are important throughout the product lifecycle.

When evaluating a supplier, consider technical documentation, sample verification, production consistency, customization feasibility and long-term sourcing requirements.

Industrial contactor selection guide ↗

FAQ

Frequently
Asked
Questions

Discuss your requirements

Send us your specifications, drawings or existing part number to discuss product suitability, customization feasibility and quotation requirements.

Request a quote
What should I check before selecting this contactor?

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

Can I request a customized contactor?

Customization depends on the model and technical requirements. Share your specifications or drawings so the feasibility of your requested configuration can be reviewed.

Can I request samples before bulk purchasing?

Sample availability, cost and lead time should be confirmed for the selected model before placing an order.

What information is needed for a quotation?

Provide the model number, required quantity, electrical specifications, intended application and any special technical or packaging requirements.