Automated industrial inspection equipment

PRODUCT LINE / CUSTOM SOLUTIONS / TECHNICAL SUPPORT

OEM & Custom Solutions

Explore product specifications, application requirements and customization options for your equipment.

Shanghai Tianyi Hang company reception

FOR OEMS / REF 03

THZ-300T Contactor

Suitable for programmable power supplies, uninterruptible power supply (UPS) systems, forklifts, electric vehicles, sightseeing vehicles, construction machinery, and other similar systems.

  • Application-based electrical specification review
  • Electrical and mechanical compatibility
  • Technical discussion for OEM requirements
  • Sample evaluation and bulk sourcing coordination
Request a quote

Industrial Contactor Specifications

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

THZ-300T Contactor

Load current
300 A
Contact arrangement
1 Form A
Type
Magnetic latch
Model and construction
TypeMagnetic latch
Load current300A
series breakdownT series
Contact Type1 Form Open contact
Permanent MagnetNo Blowouts
Coil Voltage24 Vd.c.
Load voltage24 Vd.c.
Special Codecustomer demand(Only for special requirements)

Product characteristics

  • 1.The main contact adopts a double breakpoint structure;
  • 2.Using rubber sealing ring structure, sealing grade up to IP65;
Coil ratings
Rated Voltage
Vd.c.
Operate Voltage
Vd.c.(at
-40 ℃~75 ℃)
Release Voltage
Vd.c. (at
-40 ℃~75 ℃)
Coil Resistance
Ω(at 23 ℃)
Coil Power
W(at
-40 ℃~75 ℃)
24≤18≤2.445×(1±10%)pprox. 14W
  • Contact Arrangement: 1 Form A
  • Contact Material: Copper Alloy
  • Contact Resistance: ≤1 mΩ (at 20 A)
  • Contact Rating: 300 A (185 mm2 wire)
  • Max. Breaking Current: see4.1
  • Max. Switching Voltage: 30 Vd.c.
  • Min. Applicable Load: 6 Vd.c. 1 A
Current endurance
CurrentDuration
300 Acont.
375 A1 h
600 A20 min
1200 A30 s
2400 A10 s

Condition for current endurance

  • 1.Ambient temperature:75 ℃;
  • 2.Supply rated voltage to coil
  • 3.The cross section area of wire is 185 mm² .
Electrical endurance
Product
model
Ambient
Temperature
Contact RatingON:OFFElectrical
Endurance
THZ-300T/24Room
Temperature
Make-Break:( L/R≤1 ms)
Steady 300 A
Contact Voltage 24 Vd.c.
1 s:9 s50000≥(ops)
Make-Break:( L/R≤1 ms)
Steady 375 A
Contact Voltage 24 Vd.c.
1 s:9 s120≥(ops)
Make-Break: ( L/R≤1 ms)
Steady 1200 A
Contact Voltage 48 Vd.c.
1 s:9 s1≥(ops)
Model weight
Product modelUnit Weight
THZ-300T/1C24·24345g

Please refer to the technical datasheet for the exact ratings and operating conditions of each model.

TECHNICAL DRAWINGS

Drawings & diagrams

Open a figure to inspect the dimensions and configuration details.

Designed Around Your
Equipment Requirements

Industrial testing station

Application-Based Selection

Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.

Component testing and inspection

Electrical and Mechanical Compatibility

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

Industrial manufacturing workshop

OEM and Customization Support

Discuss your application, technical parameters and installation constraints with our team. Available options depend on the product platform, engineering feasibility and order requirements.

Industrial Contactor
Applications

  • Industrial machinery and equipment
  • Motor control and electrical control panels
  • Power switching and distribution systems
  • OEM equipment development
  • Application-specific electrical assemblies

Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.

Shanghai Tianyi Hang production floor

OEM Industrial Contactor
Sourcing

For equipment manufacturers, consistent specifications and reliable supply arrangements are important throughout the product lifecycle.

When evaluating a supplier, consider technical documentation, sample verification, production consistency, customization feasibility and long-term sourcing requirements.

Industrial contactor selection guide ↗

FAQ

Frequently
Asked
Questions

Discuss your requirements

Send us your specifications, drawings or existing part number to discuss product suitability, customization feasibility and quotation requirements.

Request a quote
What should I check before selecting this contactor?

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

Can I request a customized contactor?

Customization depends on the model and technical requirements. Share your specifications or drawings so the feasibility of your requested configuration can be reviewed.

Can I request samples before bulk purchasing?

Sample availability, cost and lead time should be confirmed for the selected model before placing an order.

What information is needed for a quotation?

Provide the model number, required quantity, electrical specifications, intended application and any special technical or packaging requirements.