Automated industrial inspection equipment

PRODUCT LINE / CUSTOM SOLUTIONS / TECHNICAL SUPPORT

OEM & Custom Solutions

Explore product specifications, application requirements and customization options for your equipment.

Shanghai Tianyi Hang company reception

FOR OEMS / REF 19

Battery Disconnect Switch

Review the electrical ratings, connection options and installation details for this switch configuration.

  • Application-based electrical specification review
  • Electrical and mechanical compatibility
  • Technical discussion for OEM requirements
  • Sample evaluation and bulk sourcing coordination
Request a quote

Industrial Switch Specifications

Confirm the circuit ratings, switch positions, mounting dimensions and terminal connections for your application.

Battery Disconnect Switch

Rated switched load
300 A at 48 V DC
Protection rating
IP67

Characteristics

  • Rated load value: DC 48V, 300A (can be switched on and off with load); non-load switching can reach DC 80V, 300A.
  • IP67 protection rating, waterproof and dustproof.
  • A rotation angle of 90° ensures reliable contact and disconnection of the switch points, making it easy to identify the position of the switch.
  • Products with an ending number 'H' are equipped with magnetic blow-off attachments, capable of carrying a load with a switching capacity of up to 90V and 200A.
  • Products with a suffix of G are equipped with an auxiliary switch that connects and disconnects simultaneously with the main circuit. The lead length can be customized according to customer requirements.
  • Type A can be locked in the OFF position; Type B can be locked in both the ON and OFF positions.
Performance parameters
Rated voltage of the main contactVDC48V (switchable load capacity), 80V (non-switchable load capacity)
Rated current of the main contact pointA300A
Main contact operating voltage (high voltage type)VDC90V (Capable of Load Switching)
Main contact operating current (high voltage type)A200A(DC90V)
Main contact voltage dropmV≤150mV
Main contact overload currentA1200A~2min
1600A~30sec
2000A~3sec
Electrical lifespantimes5000
Mechanical lifespantimes60,000
Auxiliary contact operating voltageVDC100V
Rated current of auxiliary contactsA0.5A
Dielectric StrengthVAC1000VAC 50 Hz/60 Hz, 1 minute (leakage current not exceeding 5mA)
Insulation ResistanceMΩAbove 100 (under 500VDC conditions)
Working Temperature℃-40~+85
Work Humidity/5%~90%
ImpactG6G/11ms
VibrationG4G/50~2000Hz
Protection Level/IP67
Bolt Size/M10
Weightg330
Cross-sectional area of the connection cable (under rated load)mm2≥70mm2
Auxiliary contact connectorDT04-2P

Working Principles

  • 1.When the handle is rotated 90° clockwise, the drive shaft pushes the contact piece to connect with the terminal, closing the current circuit of the two terminal posts.
  • 2.When the joystick is rotated 90° counterclockwise, the spring force of the transmission shaft retracts, causing the current to disconnect at the two terminal posts.
  • Circuit Connection Instructions
  • 1.Connection of the power supply positive terminal: The disconnection point is located between the power supply and the load. When the switch is turned off, it disconnects all power to the load.
  • 2.Connection of the power supply negative terminal: The disconnection point is between the power supply and ground. When the switch is open, there may be a potential short-circuit current between the load and the ground.
  • Shape Diagram
  • Precautions for Use
  • ※ To enhance anti-interference capability, products with auxiliary contacts (designated by a suffix 'G') should pay attention to the differentiation of positive and negative polarity of the main contact terminals during installation.
  • ※ The torque range for tightening the screws is specified below; exceeding the maximum torque value may lead to product rupture.
  • 1)Contact terminal tightening torque: 17-24 N·m
  • 2) Torque at the installation location (for 2×M8 bolts): 24 N·m (maximum)
  • ※ Do not allow debris and oil stains to contaminate the main terminals, and ensure that the external terminal connections make reliable contact with the product's main terminals; otherwise, this may cause the terminals to overheat significantly. Additionally, the connecting lead cables must meet the required cross-sectional area to prevent overheating, which could affect the product's lifespan.

Please refer to the technical datasheet for the exact ratings and operating conditions of each model.

TECHNICAL DRAWINGS

Drawings & diagrams

Open a figure to inspect the dimensions and configuration details.

Designed Around Your
Equipment Requirements

Industrial testing station

Application-Based Selection

Check the model drawings and terminal configuration against your equipment before integrating the switch.

Component testing and inspection

Electrical and Mechanical Compatibility

Confirm the circuit ratings, switch positions, mounting dimensions and terminal connections for your application.

Industrial manufacturing workshop

OEM and Customization Support

Discuss your application, technical parameters and installation constraints with our team. Available options depend on the product platform, engineering feasibility and order requirements.

Industrial Switch
Applications

  • Vehicle electrical systems
  • OEM equipment assemblies
  • Application-specific control circuits

Check the model drawings and terminal configuration against your equipment before integrating the switch.

Shanghai Tianyi Hang production floor

OEM Industrial Switch
Sourcing

For equipment manufacturers, consistent specifications and reliable supply arrangements are important throughout the product lifecycle.

When evaluating a supplier, consider technical documentation, sample verification, production consistency, customization feasibility and long-term sourcing requirements.

FAQ

Frequently
Asked
Questions

Discuss your requirements

Send us your specifications, drawings or existing part number to discuss product suitability, customization feasibility and quotation requirements.

Request a quote
What should I check before selecting this switch?

Confirm the circuit ratings, switch positions, mounting dimensions and terminal connections for your application.

Can I request a customized contactor?

Customization depends on the model and technical requirements. Share your specifications or drawings so the feasibility of your requested configuration can be reviewed.

Can I request samples before bulk purchasing?

Sample availability, cost and lead time should be confirmed for the selected model before placing an order.

What information is needed for a quotation?

Provide the model number, required quantity, electrical specifications, intended application and any special technical or packaging requirements.