Automated industrial inspection equipment

PRODUCT LINE / CUSTOM SOLUTIONS / TECHNICAL SUPPORT

OEM & Custom Solutions

Explore product specifications, application requirements and customization options for your equipment.

Shanghai Tianyi Hang company reception

FOR OEMS / REF 17

WDK-3AL / WDK-3BL Emergency Disconnect Switch

Review the electrical ratings, connection options and installation details for this switch configuration.

  • Application-based electrical specification review
  • Electrical and mechanical compatibility
  • Technical discussion for OEM requirements
  • Sample evaluation and bulk sourcing coordination
Request a quote

Industrial Switch Specifications

Confirm the circuit ratings, switch positions, mounting dimensions and terminal connections for your application.

WDK-3AL / WDK-3BL Emergency Disconnect Switch

Maximum load voltage
96 V DC
Rated fault current breaking capacity (5 ms)
1,000 A at 96 V DC
  • Features:
  • It has a set of bridge normally open contacts, preset with permanent magnets,
  • and a maximum load voltage of 96V DC.normally open contact、a group of auxiliary
  • contact.
  • Rated fault current breaking capacity (Icn) 5ms: 1000A×96V DC;
  • Fully in line with ROHS requirements.
Construction and materials
Connection typeBolt connectorMounting methodPanel screw mounting
Stationary contactsSilver-copper alloyMoving contactsSilver-copper alloy
Base materialPhenol-wakeplasticHandle materialABS engineering plastic
Electrical life10,000timeOperating temperature-40℃~+85℃
Mechanical life100,000timeOperating humidity5%~90%
Protection ratingIP20
Model specifications
Product ParameterUnitsWDK-3ALWDK-3BL
Rated main contact voltageVDC4896
Rated main contact currentA250
Continuous operating current of main contactA250
contact dropmV≤80
Maximum breaking capacity of main contactA1000 A; energization time ≤ 5 ms
Pull force of the handle upwardsVDC35~60
pressing down on the handleA15~50
Electrical life of main contactN10000
Mechanical lifeN100,000
Voltage resistanceVAC1000VAC 50 Hz/60 Hz ,1 minute(leakage current does not exceed 5mA)
Insulation resistanceMΩ100(500VDC)
Operating temperature℃40~+85
Operating humidity/5%~90%
Impactm/s196
VibrationmmSinusoidal vibration, 1.5 mm double amplitude, 10 Hz~500 Hz, acceleration 49 m/s²
Rated duty system/Uninterrupted
Weight (approx)g500
Degree of Protection/IP20
Enforce the standard/GB/T 14048.5/IEC60947-5-1

Installation instructions

  • Remove the red handle first, then attach the product to your device and secure it with M5 screws with a 47mm spacing between the mounting holes, then attach the red handle and tighten the handle. When the handle is pushed and pulled, there is a crisp sound, and the assembly is completed.

Please refer to the technical datasheet for the exact ratings and operating conditions of each model.

TECHNICAL DRAWINGS

Drawings & diagrams

Open a figure to inspect the dimensions and configuration details.

Designed Around Your
Equipment Requirements

Industrial testing station

Application-Based Selection

Check the model drawings and terminal configuration against your equipment before integrating the switch.

Component testing and inspection

Electrical and Mechanical Compatibility

Confirm the circuit ratings, switch positions, mounting dimensions and terminal connections for your application.

Industrial manufacturing workshop

OEM and Customization Support

Discuss your application, technical parameters and installation constraints with our team. Available options depend on the product platform, engineering feasibility and order requirements.

Industrial Switch
Applications

  • Vehicle electrical systems
  • OEM equipment assemblies
  • Application-specific control circuits

Check the model drawings and terminal configuration against your equipment before integrating the switch.

Shanghai Tianyi Hang production floor

OEM Industrial Switch
Sourcing

For equipment manufacturers, consistent specifications and reliable supply arrangements are important throughout the product lifecycle.

When evaluating a supplier, consider technical documentation, sample verification, production consistency, customization feasibility and long-term sourcing requirements.

FAQ

Frequently
Asked
Questions

Discuss your requirements

Send us your specifications, drawings or existing part number to discuss product suitability, customization feasibility and quotation requirements.

Request a quote
What should I check before selecting this switch?

Confirm the circuit ratings, switch positions, mounting dimensions and terminal connections for your application.

Can I request a customized contactor?

Customization depends on the model and technical requirements. Share your specifications or drawings so the feasibility of your requested configuration can be reviewed.

Can I request samples before bulk purchasing?

Sample availability, cost and lead time should be confirmed for the selected model before placing an order.

What information is needed for a quotation?

Provide the model number, required quantity, electrical specifications, intended application and any special technical or packaging requirements.