Application-Based Selection
Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.
PRODUCT LINE / CUSTOM SOLUTIONS / TECHNICAL SUPPORT
OEM & Custom Solutions
Explore product specifications, application requirements and customization options for your equipment.

FOR OEMS / REF 11
This series of products is of sealed design, with a protection rating up to IP66. It is suitable for applications in harsh operating environments, such as construction machinery, electric vehicles, and fields requiring explosion-proof protection.
Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

| Product Model | TCC200/1C12·48 | TCC200/1C24·48A | TCC200/1C48·48A | |
|---|---|---|---|---|
| Rated voltage of contact circuit (V DC) | 48 | 48 | 48 | |
| Rated current of contact circuit (A) | 200 | 200 | 200 | |
| Rated coil voltage (V DC) | 12 | 24 | 48 | |
| Cold-state operating voltage (V) | Maximum pickup voltage at (20±5)℃ | 8.4 | 16.8 | 33.6 |
| Minimum release voltage at (20±5)℃ | 1.2 | 2.4 | 4.8 | |
| Maximum cold-start inrush current at (20±5)℃ (A) | 0.9 | 0.5 | 0.5 | |
| Coil voltage fluctuation range | ±20% | |||
| Contact voltage drop (mV) | ≤80 | |||
| Insulation resistance (MΩ) | 20 | |||
| Insulation dielectric strength | 1000 V AC (rms), 50 Hz, 1 min, no flashover or breakdown | |||
| Maximum operating time at rated voltage (without coil suppression or freewheeling diode) | Pick-up | 30ms | ||
| Release | 30ms | |||
| Maximum contact bounce time on opening | 5ms | |||
| Maximum switching capacity of main contacts | One makeandbreak operation at 4 times rated load current, with 5 ms energization time | |||
| Electrical life at rated voltage (cycles) | 6,000 | |||
| Mechanical life (cycles) | 100,000 | |||
| Operating duty (or Duty cycle) | Continuous duty | |||
| Product Model | TCC200/1C12·48 | TCC200/1C24·48A | TCC200/1C48·48A |
|---|---|---|---|
| Ambient Temperature | -40℃ ~ +70℃ | ||
| Relative Humidity | 98% at 20℃ | ||
| Vibration | 1~50 Hz (at 1~10 Hz, amplitude 25/f²; at 10~50 Hz, amplitude 250/f²) | ||
| Shock | 30m/s | ||
| Mounting Method | Any orientation | ||
| Degree of Protection | IP66 (according to GB 4208-2008) | ||
Please refer to the technical datasheet for the exact ratings and operating conditions of each model.
TECHNICAL DRAWINGS
Open a figure to inspect the dimensions and configuration details.

Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.

Confirm the load type, contact and coil voltages, switching duty and mounting requirements.

Discuss your application, technical parameters and installation constraints with our team. Available options depend on the product platform, engineering feasibility and order requirements.
Contactors are used in industrial machinery, motor control systems and power control assemblies. Model suitability depends on the electrical load, switching frequency and system design.

For equipment manufacturers, consistent specifications and reliable supply arrangements are important throughout the product lifecycle.
When evaluating a supplier, consider technical documentation, sample verification, production consistency, customization feasibility and long-term sourcing requirements.
Industrial contactor selection guide ↗FAQ
Send us your specifications, drawings or existing part number to discuss product suitability, customization feasibility and quotation requirements.
Request a quoteConfirm the load type, contact and coil voltages, switching duty and mounting requirements.
Customization depends on the model and technical requirements. Share your specifications or drawings so the feasibility of your requested configuration can be reviewed.
Sample availability, cost and lead time should be confirmed for the selected model before placing an order.
Provide the model number, required quantity, electrical specifications, intended application and any special technical or packaging requirements.